This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
current_release [2016/04/22 21:43] c0nnex [FIP Support] |
current_release [2016/12/13 19:15] (current) c0nnex [Download] |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== SPAD.neXt Current Release: 0.9.1 ====== | + | ====== SPAD.neXt Current Release: 0.9.5 ====== |
- | + | ||
- | Requirements:\\ | + | |
- | free unregistered Version of SPAD.neXt : FSUIPC (unpaid version) is needed\\ | + | |
===== Known incompatibilities ===== | ===== Known incompatibilities ===== | ||
Line 10: | Line 6: | ||
* Linda: Please disable all Panel-Access within Linda, else it will interfere with the panel communication | * Linda: Please disable all Panel-Access within Linda, else it will interfere with the panel communication | ||
* SST (Saitek Profiler): If you use SST for any device, disable those in SPAD.neXt | * SST (Saitek Profiler): If you use SST for any device, disable those in SPAD.neXt | ||
+ | * DirectOutput: SAPD.neXt handles the FIP directly. It's safe to uninstall Saitek Directoutput Drivers. | ||
+ | * MSI Afterburner: In rare cases MSI Afterburner will make SPAD.neXt crash. Please exclude SPAD.neXt from it. | ||
+ | |||
+ | Please note. Current public release does not support the X.52 LCD Display fully yet. An Update will be released as soon as possible. | ||
===== FIP Support ===== | ===== FIP Support ===== | ||
- | Currently only one gauge per FIP-Device is supported. | + | |
Requirements: | Requirements: | ||
- | * Saitek DirectOutput Driver 64Bit Version 7.0.40.0 or newer. Recommended: [[ftp://ftp.saitek.com/pub/software/full/FIP/Pro_Flight_Instrument_Panel_7_0_47_1_x64_Drivers.exe|7.0.47.1]] | ||
* SimConnect must be **enabled** within SPAD.neXt | * SimConnect must be **enabled** within SPAD.neXt | ||
- | By default SPAD.neXt will manage the DirectOutput Services. It will try to start it if it's not running and shut it down when exiting. | ||
- | |||
- | If you do not want this behavior, you can change it in Settings->Application "Manage DirectOutput Services" | ||
- | |||
- | If you want to have the DirectOutput Service managed by SPAD.neXt, you can safely change the startup mod of the service to "manual", but make sure SPAD.neXt has the necessary rights to start it. | ||
- | |||
- | If you get an error ''DirectOutput Service: System Invalid Operation Exception Cannot open SaiDOutput service on computer '.''' this means that SPAD.neXt had no pernmissions to control the DirctOutput Service. Either configure SPAD.neXt to run as Administrator or disable the "Manage DirectOutput Service" option in Settings->Application. | ||
The FIP Support is 100% compatible with Saitek implementation, even the bugs haven been implemented. | The FIP Support is 100% compatible with Saitek implementation, even the bugs haven been implemented. | ||
Line 37: | Line 29: | ||
SPAD.neXt implementation add some new possibilities to the gauges. If you are a gauge developer see [[gauges:spad.next_extensions|SPAD.neXt Gauge Extensions]] for details. | SPAD.neXt implementation add some new possibilities to the gauges. If you are a gauge developer see [[gauges:spad.next_extensions|SPAD.neXt Gauge Extensions]] for details. | ||
- | ===== Yoke Support ===== | ||
- | |||
- | The Pro Flight Yoke and Cessna Yoke are supported. | ||
- | To be able to use the mode shifting, you will need to make a [[help:yoke_mode_warning|manual change]] to your system. You will see a warning if this change needs to be made. | ||
===== LVAR Support ===== | ===== LVAR Support ===== | ||
Line 53: | Line 41: | ||
- | [[https://www.fsgs.com/download/SPAD.neXt.setup.zip|SPAD.neXt Installer]] | + | [[http://www.spadnext.com/download/download-spad-next.html|SPAD.neXt Installer]] |